Data and Calculations

Home
Here is my raw data for all of my measurements taken during the lab. This includes every single valid measurement that has ever been made in the history of mankind. (That was a joke.)

Aluminum
WaterAluminum
RunmCTemp ITemp F=mCTemp ITemp F
193.884.184016.7519.75=17.98C10019.72
298.514.183218.1921.22=17.97C10021.22
399.854.183217.5020.70=17.97C10020.70
491.964.183217.9019.00=5.97 C10019.00
596.224.184915.7518.90=17.98C10018.90
685.814.184017.3019.60=11.42C10019.60
7115.374.183217.5720.30=17.97C10020.30
895.724.181919.5022.65=17.98C10022.65
995.114.185815.0618.28=17.98C10018.28
1097.224.182518.9221.90=17.98C10021.90

Iron
WaterIron
RunmCTemp ITemp F=mCTemp ITemp F
182.594.182519.0024.05=49.67C10024.05
291.624.182519.0523.30=49.22C10023.30
392.974.184916.6521.10=49.21C10021.10
499.994.182519.5023.62=49.66C10023.62
590.384.181919.9024.55=49.66C10024.55
686.674.183217.5322.20=49.66C10022.20
783.364.182518.9922.19=31.14C10022.19
891.414.186914.4719.25=49.66C10019.25
994.984.185814.8319.34=49.66C10019.34
10115.464.184017.0020.60=49.66C10020.60

Copper
WaterCopper
RunmCTemp ITemp F=mCTemp ITemp F
1120.544.181919.9123.25=57.26C10023.25
261.314.183218.3024.50=56.52C10024.50
388.174.184016.7021.20=57.26C10021.20
496.044.184916.0717.20=14.25C10017.20
5103.294.183218.2922.10=57.25C10022.10
6124.254.184017.1020.51=57.25C10020.51
7101.404.181919.9023.70=56.45C10023.70
884.504.183218.0122.81=56.53C10022.81
991.434.181321.0025.42=57.26C10025.42

Zinc
WaterZinc
RunmCTemp ITemp F=mCTemp ITemp F
182.614.181920.3025.12=57.26C10025.12
2115.154.181320.7124.20=55.55C10024.20
372.354.182519.4024.38=55.56C10024.38
482.274.181320.7925.65=55.56C10025.65
5107.694.182519.0022.85=56.40C10022.85
686.114.180821.5025.80=56.41C10025.80
768.474.182518.5524.20=57.83C10024.20
887.214.182518.7023.40=57.83C10023.40
9100.004.183218.3122.38=57.83C10022.38
10116.254.182519.4022.91=57.83C10022.91

Lead
WaterLead
RunmCTemp ITemp F=mCTemp ITemp F
198.034.183218.4919.98=58.25C10019.98
277.484.181321.2022.91=58.41C10022.91
372.794.181920.4022.30=59.14C10022.30
494.444.181919.6321.20=59.04C10021.20
554.774.181920.0022.70=59.04C10022.70
689.364.180820.9822.57=59.04C10022.57
798.264.180821.5022.91=59.04C10022.91
885.494.184915.9617.74=58.40C10017.74
993.634.186914.2815.87=54.99C10015.87
1085.864.184016.5918.31=58.40C10018.31

Glass
WaterGlass
RunmCTemp ITemp F=mCTemp ITemp F
197.354.181921.3623.26=11.17C10023.26
285.954.182519.2021.62=11.34C10021.62
3107.004.182519.5021.29=11.34C10021.29
493.484.180423.1325.40=11.34C10025.40
585.914.180422.5024.90=11.17C10024.90
678.634.183218.1020.50=10.97C10020.50
763.324.183217.8320.70=10.97C10020.70
892.584.181919.8721.75=10.97C10021.75
974.774.182518.5720.83=10.98C10020.83
1099.694.183218.4420.27=10.97C10010.54
1199.124.181320.7122.59=10.54C10022.59

Brass
WaterBrass
RunmCTemp ITemp F=mCTemp ITemp F
181.774.181919.5124.00=54.49C10024.00
296.014.182519.5123.41=54.49C10023.41
391.504.181920.3024.29=53.95C10024.29
489.594.182519.4023.50=53.89C10023.50
589.034.180024.2027.71=53.95C10027.71
693.284.183218.0722.21=54.49C10022.21
791.494.184017.3321.67=54.49C10021.67
897.824.182518.7022.50=54.49C10022.50
981.894.181920.1524.40=54.49C10024.40
1073.824.181920.1524.80=54.49C10024.80
11106.274.184916.0319.61=53.96C10019.61

To find ΔT, you take your set of data, and subtract the final temperature from the initial temperature. For example:
RunmCTemp ITemp F=mCTemp ITemp F
585.914.180422.5024.90=11.17C10024.90
Calculation: 24.90-22.50 = 2.40 and 100-24.90 = 75.10 so the new table looks like this:
RunmCΔT=mCΔT
585.914.18042.40=11.17C75.10
^_^ Well, there it is. Now, watch as I apply this to all of my measurements.
Aluminum
WaterAluminum
RunmCΔT=mCΔT
193.884.18402.97=17.98C80.28
298.514.18323.03=17.97C78.78
399.854.18323.20=17.97C79.30
491.964.18321.10=5.97 C81.00
596.224.18493.15=17.98C81.10
685.814.18402.30=11.42C80.4
7115.374.18322.73=17.97C79.70
895.724.18193.15=17.98C77.35
995.114.18583.22=17.98C81.72
1097.224.18252.98=17.98C78.10

Iron
WaterIron
RunmCΔT=mCΔT
182.594.18255.05=49.67C75.95
291.624.18254.25=49.22C76.70
392.974.18494.45=49.21C78.90
499.994.18254.12=49.66C76.38
590.384.18194.65=49.66C75.45
686.674.18324.67=49.66C77.80
783.364.18253.20=31.14C77.81
891.414.18694.78=49.66C80.75
994.984.18584.51=49.66C80.66
10115.464.18403.60=49.66C79.40

Copper
WaterCopper
RunmCΔT=mCΔT
1120.544.18193.34=57.26C76.75
261.314.18326.20=56.52C75.50
388.174.18404.50=57.26C78.80
496.044.18491.13=14.25C82.80
5103.294.18323.81=57.25C77.90
6124.254.18403.41=57.25C79.49
7101.404.18193.80=56.45C76.30
884.504.18324.80=56.53C77.19
991.434.18134.42=57.26C74.58

Zinc
WaterZinc
RunmCΔT=mCΔT
182.614.18194.82=57.26C74.88
2115.154.18133.49=55.55C75.80
372.354.18254.98=55.56C75.62
482.274.18134.86=55.56C74.35
5107.694.18253.85=56.40C77.15
686.114.18084.30=56.41C74.20
768.474.18255.65=57.83C75.80
887.214.18254.70=57.83C76.60
9100.004.18325.07=57.83C77.62
10116.254.18253.51=57.83C77.09

Lead
WaterLead
RunmCΔT=mCΔT
198.034.18321.49=58.25C80.02
277.484.18131.71=58.41C77.09
372.794.18191.90=59.14C77.70
494.444.18191.57=59.04C78.80
554.774.18192.70=59.04C77.30
689.364.18081.59=59.04C77.43
798.264.18081.41=59.04C77.09
885.494.18491.78=58.40C82.26
993.634.18691.59=54.99C84.13
1085.864.18401.72=58.40C81.69

Glass
WaterGlass
RunmCΔT=mCΔT
197.354.18191.90=11.17C76.74
285.954.18252.42=11.34C78.38
3107.004.18251.79=11.34C78.71
493.484.18042.27=11.34C74.60
585.914.18042.40=11.17C75.10
678.634.18322.40=10.97C79.50
763.324.18322.87=10.97C79.30
892.584.18191.88=10.97C78.25
974.774.18252.26=10.98C79.17
1099.694.18321.83=10.97C89.46
1199.124.18131.88=10.54C77.41

Brass
WaterBrass
RunmCΔT=mCΔT
181.774.18194.49=54.49C76.00
296.014.18253.90=54.49C76.59
391.504.18193.99=53.95C75.71
489.594.18254.10=53.89C76.50
589.034.18003.51=53.95C72.29
693.284.18324.14=54.49C77.79
791.494.18404.34=54.49C78.33
897.824.18253.80=54.49C77.50
981.894.18194.25=54.49C75.60
1073.824.18194.65=54.49C75.20
11106.274.18493.58=53.96C80.39

To calculate specific heat capacity, you isolate C. Here is an example: border=3>
(85.91) (4.1804)(2.40)=(11.17)(C)(75.10)
85.91(4.1804)2.40=11.17(C)75.10
1.03=C
Once again, see it applied to all the data!
Aluminum
Run#=C
10.887=C
20.883=C
30.938=C
40.875=C
50.871=C
60.900=C
70.920=C
80.906=C
90.892=C
100.862=C

Iron
Run#=C
10.461=C
20.432=C
30.446=C
40.453=C
50.469=C
60.437=C
70.462=C
80.456=C
90.447=C
100.442=C

Copper
Run#=C
10.382=C
20.373=C
30.368=C
40.385=C
50.370=C
60.389=C
70.374=C
80.389=C
90.398=C

Zinc
Run#=C
10.389=C
20.398=C
30.383=C
40.404=C
50.398=C
60.370=C
70.370=C
80.386=C
90.379=C
100.384=C

Lead
Run#=C
10.129=C
20.123=C
30.126=C
40.133=C
50.135=C
60.130=C
70.127=C
80.133=C
90.135=C
100.130=C

Glass
Run#=C
10.903=C
20.979=C
30.897=C
41.05=C
51.03=C
60.905=C
70.874=C
80.885=C
90.813=C
100.908=C
110.955=C

Brass
Run#=C
10.372=C
20.376=C
30.375=C
40.374=C
50.337=C
60.382=C
70.389=C
80.367=C
90.354=C
100.351=C
110.367=C
To calculate percent error, we simply take the absolute value of the measurement minus the actual value, divided by the actual value times 100. That is:

measurement-actual value

actual value

times 100. And one last time, let us see all the measurements represented this way.
Aluminum
WaterAluminum
Runerror=#
1error=1.5%
2error=1.9%
3error=4.2%
4error=2.7%
5error=3.2%
6error=0%
7error=2.7%
8error=0.667%
9error=0.89%
10error=4.0%

Iron
WaterIron
Runerror=#
1error=2.7%
2error=3.8%
3error=0.7%
4error=0.89%
5error=4.5%
6error=2.67%
7error=2.8%
8error=1.56%
9error=0.4%
10error=1.6%

Copper
WaterCopper
Runerror=#
1error=0.7%
2error=3.1%
3error=4.4%
4error=0%
5error=3.89%
6error=1%
7error=3.61%
8error=1.03%
9error=3.38%

Zinc
WaterZinc
Runerror=#
1error=0.26%
2error=3.37%
3error=1.28%
4error=4.1%
5error=2.6%
6error=4.6%
7error=4.6%
8error=0.52%
9error=2.32%
10error=1.03%

Lead
WaterLead
Runerror=#
1error=0%
2error=4.7%
3error=2.3%
4error=3%
5error=4.65%
6error=0.78%
7error=1.6%
8error=3.1%
9error=4.65%
10error=0.775%

*not applicable for glass and brass. Home